findmyKOL
Clinical trialNCT02089672CompletedObservational

RF Lesion Monitoring With 8mm IntellaTip MiFi XP

SponsorEmory UniversityEnrollment30ArrhythmiaAtrial Flutter
View the registry record on ClinicalTrials.gov

Summary

The lay summary the sponsor registered on ClinicalTrials.gov.

Abnormal heart rhythms or arrhythmias are often managed by a procedure in which a catheter is introduced into the heart. These catheters can then cauterize abnormally functioning portions of the heart muscle with the hope of returning the heart to a more effective rhythm. In the process of performing such a procedure, called a catheter ablation, an operator must be able to accurately sense electrical activity displayed on computer screens in different parts of the heart, provide sufficient localized energy to the abnormally behaving tissue (ideally without damaging uninvolved heart structures), and accurately reassess the electrical activity of the heart to ensure the spot in the heart has been cauterized. When sensing electrical activity of the heart, specialized catheters produce recordings on a computer screen known as electrograms (EGM). To produce this recording conventional catheters commonly use a positive and negative electrode, from which the difference between the two provides the EGM. The distance between the two electrodes varies from device to device. The greater the distance between them, the less accurate the measurement of local electrical activity becomes. This may result in poorly localized or excessive use of energy that could be damaging to normal heart structures or put the patient at risk for the return or development of additional arrhythmias. The IntellaTip MiFi catheter has been constructed with a specialized sensing tip that uses "microelectrodes" that are relatively close in proximity (\<1 mm apart) with the hope of improving the sensing capability of the device. This study will analyze the signals obtained from this FDA-approved catheter in people undergoing a catheter ablation procedure. The study will examine signals after the procedure is finished and will not prolong or differ the process from a standard ablation procedure. The goal of this study is to determine the ability of the microelectrodes to distinguish ablated, or cauterized versus non-cauterized tissue.

Investigators

The overall officials registered on this study. Names that resolve to a findmyKOL profile link to it; the rest are shown as registered.

A profile link is shown only when the registered name resolves to a person record with a confident, namesake-checked match; ambiguous names stay unlinked.

Sites

1 registered facility, with the per-site recruitment status where the registry publishes one. ClinicalTrials.gov does not publish per-site enrollment counts.

United States
  • Emory University Hospital

    Atlanta, Georgia, United States

Site investigator names are published by ClinicalTrials.gov only while a study recruits, so completed studies list sites without them.

Drugs studied

No drug or biological interventions are in our data for this study. It may test a procedure, device or behavioral intervention, or the intervention list isn't in our current snapshot. See the registry record ↗. Why? →

Registration & key dates

Registry attributes as recorded on the ClinicalTrials.gov study record.

Start
30 Apr 2014
Primary completion
30 Nov 2015
Completion
30 Nov 2015
Last update posted
17 Nov 2015
Registered enrollment
30
Registry id
NCT02089672

Source: ClinicalTrials.gov, via the CTTI AACT database, data as of 24 Aug 2026. Registry facts are shown as registered by the study sponsor; findmyKOL does not interpret them.