findmyKOL
Clinical trialNCT02095977UnknownInterventional

Insulation Failure in St. Jude Riata Leads

SponsorHartford HospitalEnrollment30Implanted With Any Currently (and Any Future) FDA-approved Medtronic ICD or CRT Deviceto Which is Attached a St. Jude Riata Lead
View the registry record on ClinicalTrials.gov

Summary

The lay summary the sponsor registered on ClinicalTrials.gov.

A recent study evaluated the Manufacturer and User Facility Device Experience (MAUDE) database, which contains reports of adverse events involving medical devices6,9. The FDA updates the database every two months. A total of 107 Riata leads with reported inside-out insulation breaks were found, of which 105 were available for analysis. The average age of the leads was 62.1+/-18.6 months. A total of 226 insulation defects were found with 143 inside-out insulation abrasions. Twenty-eight of the 105 leads (26.7%) had inside-out insulation defects underneath one or more of the high voltage-shocking coil. Of these, 23 were 8F and five were 7F Riata ST leads. Exposed cables or conductors were present in 32 leads and six leads had melted cables, presumably due to one or more high voltage shocks. 22 of the 43 leads assessed (51.2%) also had abraded ETFE cable coating exposing the conductor. Noise and other sensing issues were the most common signs of failure. Seven leads were found to have externalized cables and five exhibited electrical abnormalities. 31 patients (29.5%) experienced inappropriate shocks of which 41% had abraded cables. A critical decision facing physicians is how to screen and manage patients who are found to have externalized cables. Externalized cables on fluoroscopy may precede any electrical abnormalities. Also noise may not be detected on all ICD models. A recent case report suggested that changes in lead parameters might be transient and may be missed. The lead may function normally as the high-voltage and pace-sense cables are covered with ETFE, which serves as the second insulating barrier. As this is a very thin layer (0.0015 inches) the reliability of this to withstand a high-energy shock is unknown. This may lead to failure of appropriate therapy for life threatening arrhythmias. The aim of this study is to screen patients with ICD leads that potentially could have multiple different failure mechanisms, including inside-out insulation breaks, to develop a novel new algorithm and methods to detect these defects, thereby enabling physicians to prevent complications from failure of these leads. It is hypothesized that current monitoring tools are insufficient for detecting the sometimes transient electrical failures of the Riata family of leads, and that additional device diagnostic information in combination with fluoroscopy may improve detection of electrical failures.

Investigators

The overall officials registered on this study. Names that resolve to a findmyKOL profile link to it; the rest are shown as registered.

A profile link is shown only when the registered name resolves to a person record with a confident, namesake-checked match; ambiguous names stay unlinked.

Sites

1 registered facility, with the per-site recruitment status where the registry publishes one. ClinicalTrials.gov does not publish per-site enrollment counts.

United States
  • Hartford Hospital

    Hartford, Connecticut, United States

    Steven Zweibel, MD
    Recruiting

Site investigator names are published by ClinicalTrials.gov only while a study recruits, so completed studies list sites without them.

Drugs studied

No drug or biological interventions are in our data for this study — it may test a procedure, device or behavioral intervention, or the intervention list isn't in our current snapshot. See the registry record ↗. Why? →

Registration & key dates

Registry attributes as recorded on the ClinicalTrials.gov study record.

Start
31 Jul 2013
Primary completion
30 Apr 2018
Completion
31 Jan 2019
Last update posted
8 Feb 2017
Registered enrollment
30
Registry id
NCT02095977

Source: ClinicalTrials.gov, via the CTTI AACT database, data as of 24 Aug 2026. Registry facts are shown as registered by the study sponsor; findmyKOL does not interpret them.